Version: V1.0Release Date: 2023-12-19


KGUTI
Vendor ID 545 (0x0221) Vendor Logo
Vendor Name di-soric GmbH & Co. KG
Vendor Text SOLUTIONS. CLEVER. PRACTICAL.
Vendor URL www.di-soric.com
Device ID 279 (0x000117)
DeviceFamily Kapazitive Etikettensensoren
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x0010 (Device Profile: Measuring and Switching Sensor, 1 channel), 0x4000 (Common Application Profile: Identification and Diagnosis), 0x8012 (Function Class: Teach dynamic extension), 0x8014 (Function Class: Quantity detection), 0x8101 (Function Class: Locator)
Supported Access Locks Parameter: no, Data Storage: no, Local Parameterization: no, Local User Interface: yes
Communication
IO-Link Revision V1.1
Transmission Rate38400 bit/s (COM2)
Minimum Cycle Time 3.2 ms
SIO Mode Supported yes
M-Sequence CapabilityPREOPERATE = TYPE_1_V with 8 octets on-request data
OPERATE = TYPE_2_V with 2 octets on-request data
ISDU supported
Device Variant KGUTI80-1-G3-B4
Description Kapazitiver Etikettensensor mit IO-Link
Product ID 214208
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeNon-standard connector
Connection Symbol Connection Symbol
Connection Description M8-4
- pin 1 brown; L+;
- pin 2 white; Other; Multi-I/O
- pin 3 (light) blue; L-;
- pin 4 black; C/Q;
Device Variant KGUTI80-1-G3-RB4
Description Kapazitiver Etikettensensor mit IO-Link
Product ID 214209
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeNon-standard connector
Connection Symbol Connection Symbol
Connection Description M8-4
- pin 1 brown; L+;
- pin 2 white; Other; Multi-I/O
- pin 3 (light) blue; L-;
- pin 4 black; C/Q;

ProcessData id=P_ProcessData

ProcessDataIn "Prozessdaten" id=PI_ProcessDataIn

bit length: 32
data type: 32-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer -32760 = Außerhalb des Bereichs (-), 32760 = Außerhalb des Bereichs (+), 32764 = Keine Messdaten, 0..4095 ro Messwert Messwert
2 8 8-bit Integer Skala Zeigt den Multiplikator für den Messwert: 10exp(Skala)
3 1 Boolean false = Inaktiv, true = Aktiv Schaltzustand (SSC1.2) Schaltzustand des SSC1.2
4 0 Boolean false = Inaktiv, true = Aktiv Schaltzustand (SSC1.1) Schaltzustand des SSC1.1
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 3 4

Standard Variable "Direkte Parameter - Seite 1" index=0 id=V_DirectParameters_1

description: Beinhaltet die notwendigen Parameter für Kommunikationseigenschaften und die Kennungen zur Gerätevalidierung.
data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserviert
2 112 8-bit UInteger ro Master Zykluszeit Kommunikation: Aktuelle vom Master vorgegebene Zyklusdauer für die Kommunikation. Dieser Wert bestimmt den Prozessdatenzyklus.
3 104 8-bit UInteger ro Minimale Zykluszeit Kommunikation: Minimale Zyklusdauer der Kommunikation, die das Gerät unterstützt. Dieser Wert bestimmt den kleinsten möglichen Prozessdatenzyklus.
4 96 8-bit UInteger ro Nachrichtenfähigkeit Kommunikation: Information zur Struktur und den unterstützten Eigenschaften der Kommunikationsnachrichten.
5 88 8-bit UInteger 17 ro IO-Link Revisions-ID Kommunikation: Kennung für die aktuelle Revision des Kommunikationsprotokolls.
6 80 8-bit UInteger ro Prozessdatenlänge Eingang Kommunikation: Information zu Breite und Eigenschaften der Prozesseingangsdaten (Prozessdaten vom Gerät zum Master).
7 72 8-bit UInteger ro Prozessdatenlänge Ausgang Kommunikation: Information zu Breite der Prozessausgangsdaten (Prozessdaten vom Master zum Gerät).
8 64 8-bit UInteger ro Hersteller-ID 1 Identifikation: Höchstes Oktett der Herstellerkennung. Zusammen mit dem Parameter Hersteller-ID 2 ergibt dies den 16-Bit-Wert der von der IO-Link-Gemeinschaft vergebenen eindeutigen Herstellerkennung.
9 56 8-bit UInteger ro Hersteller-ID 2 Identifikation: Niedrigstes Oktett der Herstellerkennung. Zusammen mit dem Parameter Hersteller-ID 1 ergibt dies den 16-Bit-Wert der von der IO-Link-Gemeinschaft vergebenen eindeutigen Herstellerkennung.
10 48 8-bit UInteger ro Geräte-ID 1 Identifikation: Höchstes Oktett der Gerätekennung. Zusammen mit den Parametern Geräte-ID 2 und 3 ergibt dies den 24-Bit-Wert der herstellerspezifischen Gerätekennung.
11 40 8-bit UInteger ro Geräte-ID 2 Identifikation: Mittleres Oktett der Gerätekennung. Zusammen mit den Parametern Geräte-ID 1 und 3 ergibt dies den 24-Bit-Wert der herstellerspezifischen Gerätekennung.
12 32 8-bit UInteger ro Geräte-ID 3 Identifikation: Niedrigstes Oktett der Gerätekennung. Zusammen mit den Parametern Geräte-ID 1 und 2 ergibt dies den 24-Bit-Wert der herstellerspezifischen Gerätekennung.
13 24 8-bit UInteger ro Reserviert
14 16 8-bit UInteger ro Reserviert
15 8 8-bit UInteger ro Reserviert
16 0 8-bit UInteger wo X Systembefehl Anwendung: Befehlsschnittstelle für Geräte ohne ISDU-Unterstützung. Gültigkeit und Ausführung von Befehlen werden nicht bestätigt.

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Systembefehl" index=2 id=V_SystemCommand

description: Befehlsschnittstelle für Anwendungen. Eine positive Rückmeldung zeigt die vollständige und korrekte Ausführung der angeforderten Funktion an.
data type: 8-bit UInteger
allowed values: 64 = Teach anwenden, 71 = Teach SP1 Start, 72 = Teach SP1 Stopp, 73 = Teach SP2 Start, 74 = Teach SP2 Stopp, 75 = Teach Objekt SP1, 77 = Teach Objekt SP2, 79 = Teach Abbruch, 126 = Lokalisierung Start, 127 = Lokalisierung Stopp, 129 = Anwendung rücksetzen, 131 = Back-to-box, 163 = Information zurücksetzen, 169 = Referenzwert setzen, 240 = IO-Link 1.1 system test command 240, Event 8DFE appears, 241 = IO-Link 1.1 system test command 241, Event 8DFE disappears, 242 = IO-Link 1.1 system test command 242, Event 8DFF appears, 243 = IO-Link 1.1 system test command 243, Event 8DFF disappears
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Gerätezugriffssperren" index=12 id=V_DeviceAccessLocks

description: Der Zugriff auf die Geräteparameter kann über entsprechende Flags im Parameter eingeschränkt werden.
data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Entsperrt, true = Gesperrt Parameterschreibzugriff Diese Sperre verhindert den Schreibzugriff auf alle Schreib-/Leseparameter des Geräts mit Ausnahme des Parameters 'Gerätezugriffssperren'.
2 1 Boolean false = Entsperrt, true = Gesperrt Datenhaltung Diese Sperre verhindert den Schreibzugriff auf die Geräteparameter über die Datenhaltungsmechanismen.
3 2 Boolean false = Entsperrt, true = Gesperrt Lokale Parametrierung Diese Sperre verhindert, dass die Geräteeinstellungen über die lokalen Bedienelemente am Gerät geändert werden.
4 3 Boolean false = Entsperrt, true = Gesperrt 0 Lokale Benutzerschnittstelle Die Sperre verhindert den Zugriff auf Geräteeinstellungen und -anzeigen über eine lokale Benutzerschnittstelle am Gerät. Die Benutzerschnittstelle ist deaktiviert.
Octet 0
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4 3 2 1

Standard Variable "Herstellername" index=16 id=V_VendorName

description: Herstellername, der einer Herstellerkennung zugeordnet ist.
data type: 64-octet String UTF-8
default value: "di-soric GmbH & Co. KG"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Herstellertext" index=17 id=V_VendorText

description: Zusätzliche Informationen zum Hersteller.
data type: 64-octet String UTF-8
default value: "SOLUTIONS. CLEVER. PRACTICAL."
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produktname" index=18 id=V_ProductName

description: Vollständiger Produktname.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produkt-ID" index=19 id=V_ProductID

description: Herstellerspezifische Produkt- oder Typidentifikation (z. B. Artikelnummer oder Bestellnummer).
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produkttext" index=20 id=V_ProductText

description: Zusätzliche Produktinformationen zum Gerät.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Seriennummer" index=21 id=V_SerialNumber

description: Eindeutige, herstellerspezifische Kennung des einzelnen Geräts.
data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardwarerevision" index=22 id=V_HardwareRevision

description: Eindeutige, herstellerspezifische Kennung der Hardwarerevision des einzelnen Geräts.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmwarerevision" index=23 id=V_FirmwareRevision

description: Eindeutige, herstellerspezifische Kennung der Firmwarerevision des einzelnen Geräts.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Anwendungsspezifisches Kennzeichen" index=24 id=V_ApplicationSpecificTag

description: Möglichkeit ein Gerät mit benutzer- oder anwendungsspezifischen Informationen zu kennzeichnen.
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Fehlerzähler" index=32 id=V_ErrorCount

description: Anzahl der aufgetretenen Fehler in der technologiespezifischen Anwendung seit dem letzten Einschalten oder Neustart.
data type: 16-bit UInteger
access rights: ro
dynamic

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Standard Variable "Gerätestatus" index=36 id=V_DeviceStatus

description: Anzeige des aktuellen Geräte- und Diagnosezustands.
data type: 8-bit UInteger
allowed values: 0 = Gerät ist OK, 1 = Wartung erforderlich, 2 = Außerhalb der Spezifikation, 3 = Funktionsprüfung, 4 = Ausfall
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Ausführlicher Gerätestatus" index=37 id=V_DetailedDeviceStatus

description: Liste aller aktuell anstehender Ereignisse des Geräts.
data type: Array[5] of 3-octet OctetString (subindex access not supported)
default value: 0x00,0x00,0x00
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56
subindex 1 1 1 2 2 2 3 3

octet 8 9 10 11 12 13 14  
bit offset 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 3 4 4 4 5 5 5  

Standard Variable "PD-Eingang" index=40 id=V_ProcessDataInput

description: Letzte gültige Prozesseingangsdaten des Geräts.
data type: see ProcessDataIn!
access rights: ro
dynamic

Variable "Anlagenkennzeichnung" index=25 id=V_CP_FunctionTag

description: Vom Anwender festzulegende Anlagenkennzeichnung
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Ortskennzeichnung" index=26 id=V_CP_LocationTag

description: Vom Anwender festzulegende Ortskennzeichnung
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Teachauswahl" index=58 id=V_TeachSelect

description: Auswahl des Schaltkanals, für den die Teachprozedur angewandt wird
data type: 8-bit UInteger
allowed values: 1 = SSC1.1, 2 = SSC1.2
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Teachergebnis" index=59 id=V_TeachResult

description: Teachzustand und -ergebnis
data type: 8-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 4-bit UInteger 0 = Nicht aktiv, 1 = Schaltpunkt 1 gesetzt, 2 = Schaltpunkt 2 gesetzt, 3 = Schaltpunkte 1 und 2 gesetzt, 4 = Warten auf Kommando, 5 = Aktiv, 6 = Reserviert, 7 = Fehler 0 ro Zustand Zustand
2 4 Boolean 0 ro Flag SP1 TP1 Flag SP1 TP1
3 5 Boolean 0 ro Flag SP1 TP1 Flag SP1 TP1
4 6 Boolean 0 ro Flag SP1 TP1 Flag SP1 TP1
5 7 Boolean 0 ro Flag SP1 TP1 Flag SP1 TP1
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex 5 4 3 2 1
element bit         3 2 1 0

Variable "SSC1.1 Param" index=60 id=V_SSC11_Param

description: Definiert die Schaltpunktwerte für das Schaltsignal 1.1
data type: 64-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit UInteger 0..5000 100 SP1 Definiert den Schaltpunktwert 1 des Schaltsignals
2 0 32-bit UInteger 0..5000 200 SP2 Definiert den Schaltpunktwert 2 des Schaltsignals

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC1.1 Konfig" index=61 id=V_SSC11_Config

description: Definiert die Konfigurationsparameter für das Schaltsignal 1.1
data type: 48-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 40 8-bit UInteger 0 = High-aktiv, 1 = Low-aktiv 0 Logik Definiert die logische Darstellung des Schaltsignals in den Prozessdaten
2 32 8-bit UInteger 0 = Deaktiviert, 1 = Einzelwert, 2 = Fenster, 3 = Zwei Werte 1 Modus Legt den Auswertemodus für das Schaltsignal fest
3 0 32-bit UInteger 10..100 15 Hyst Definiert die Hysterese am Schaltpunkt. Eine höhere Hysterese kann helfen, die Stabilität in kritischen Anwendungen zu erhöhen.

octet 0 1 2 3 4 5  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 2 3 3 3 3  
element bit 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "SSC1.2 Param" index=62 id=V_SSC12_Param

description: Definiert die Schaltpunktwerte für das Schaltsignal 1.2
data type: 64-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit UInteger 0..5000 100 SP1 Definiert den Schaltpunktwert 1 des Schaltsignals
2 0 32-bit UInteger 0..5000 200 SP2 Definiert den Schaltpunktwert 2 des Schaltsignals

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC1.2 Konfig" index=63 id=V_SSC12_Config

description: Definiert die Konfigurationsparameter für das Schaltsignal 1.2
data type: 48-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 40 8-bit UInteger 0 = High-aktiv, 1 = Low-aktiv 0 Logik Definiert die logische Darstellung des Schaltsignals in den Prozessdaten
2 32 8-bit UInteger 0 = Deaktiviert, 1 = Einzelwert, 2 = Fenster, 3 = Zwei Werte 0 Modus Legt den Auswertemodus für das Schaltsignal fest
3 0 32-bit UInteger 10..100 15 Hyst Definiert die Hysterese am Schaltpunkt. Eine höhere Hysterese kann helfen, die Stabilität in kritischen Anwendungen zu erhöhen.

octet 0 1 2 3 4 5  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 2 3 3 3 3  
element bit 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Serie" index=64 id=V_Lot

description: Produktionslos
data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC1.1 Einschaltverzögerung" index=66 id=V_SSC11_DS

description: Definiert die Einschaltverzögerung für das Schaltsignal des Kanals 1.1
data type: 16-bit UInteger
allowed values: 0..60000
default value: 0
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "SSC1.1 Ausschaltverzögerung" index=67 id=V_SSC11_DR

description: Definiert die Ausschaltverzögerung für das Schaltsignal des Kanals 1.1
data type: 16-bit UInteger
allowed values: 0..60000
default value: 0
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "SSC1.2 Einschaltverzögerung" index=68 id=V_SSC12_DS

description: Definiert die Einschaltverzögerung für das Schaltsignal des Kanals 1.2
data type: 16-bit UInteger
allowed values: 0..60000
default value: 0
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "SSC1.2 Ausschaltverzögerung" index=69 id=V_SSC12_DR

description: Definiert die Ausschaltverzögerung für das Schaltsignal des Kanals 1.2
data type: 16-bit UInteger
allowed values: 0..60000
default value: 0
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Schaltausgang" index=70 id=V_OutputModeinSIOMode

description: Polarität Schaltausgang
data type: 8-bit UInteger
allowed values: 0 = SSC1.1 PP, 1 = SSC1.1 NPN, 2 = SSC1.1 PNP
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Multi I/O (Pin 2)" index=71 id=V_MultiIO2

description: Betriebsmodus für Multi I/O (Pin 2)
data type: 8-bit UInteger
allowed values: 0 = Deaktiviert, 4 = SSC1.1 PP, 5 = SSC1.1 NPN, 6 = SSC1.1 PNP, 10 = Warnausgang, 16 = Teach und Benutzerschnittstelle sperren, 33 = SSC1.2 PP, 34 = SSC1.2 NPN, 35 = SSC1.2 PNP
default value: 16
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Sensormodus" index=73 id=V_OperatingMode

description: Precision: Verringerte Messgeschwindigkeit bei erhöhter Störfestigkeit. Speed: Erhöhte Geschwindigkeit bei verringerter Störfestigkeit. Standard: Ausgewogenes Mittelmaß der Modi.
data type: 8-bit UInteger
allowed values: 0 = Standard, 1 = Precision, 2 = Speed
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Pin-2-Eingangspolarität" index=76 id=V_Pin2Polarity

description: Polarität des externen (an Pin 2 anliegenden) Signals
data type: 8-bit UInteger
allowed values: 0 = High-aktiv, 1 = Low-aktiv
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "SSC1.1 SP1" index=80 id=V_TeachValuesSSC1SP1

description: Erfasste Werte während des Teachvorgangs
data type: 64-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit UInteger 0 ro TP1 Interner, unterer Teachwert
2 0 32-bit UInteger 0 ro TP2 Interner, oberer Teachwert

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC1.1 SP2" index=81 id=V_TeachValuesSSC1SP2

description: Erfasste Werte während des Teachvorgangs
data type: 64-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit UInteger 0 ro TP1 Interner, unterer Teachwert
2 0 32-bit UInteger 0 ro TP2 Interner, oberer Teachwert

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC1.2 SP1" index=82 id=V_TeachValuesSSC2SP1

description: Erfasste Werte während des Teachvorgangs
data type: 64-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit UInteger 0 ro TP1 Interner, unterer Teachwert
2 0 32-bit UInteger 0 ro TP2 Interner, oberer Teachwert

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC1.2 SP2" index=83 id=V_TeachValuesSSC2SP2

description: Erfasste Werte während des Teachvorgangs
data type: 64-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit UInteger 0 ro TP1 Interner, unterer Teachwert
2 0 32-bit UInteger 0 ro TP2 Interner, oberer Teachwert

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messwert" index=84 id=V_ProcessDataLimits

description: Minimal- und Maximalmesswert seit Gerätestart bzw. -reset
data type: 32-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit UInteger min Minimalwert seit Einschalten oder Rücksetzen
2 0 16-bit UInteger max Maximalwert seit Einschalten oder Rücksetzen

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 2 2  
element bit 15 - 8 7 - 0 15 - 8 7 - 0  

Variable "Anzahl der Schaltvorgänge für SSC1.1" index=85 id=V_SSC11_SwitchCounter

description: Anzahl der Schaltvorgänge seit Gerätestart bzw. -reset für den Schaltkanal SSC1.1
data type: 32-bit UInteger
allowed values: 0..4294967295
access rights: ro
dynamic

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Temperatur" index=86 id=V_Temperature

description: Sensortemperatur
data type: 16-bit Integer
allowed values: -400..1200
access rights: ro
dynamic

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Teachqualität" index=87 id=V_TeachQuality

description: Qualität des letzten Teachvorgangs
data type: 8-bit UInteger
allowed values: 0 = N/A, 1 = Gut, 2 = Nicht gut, 3 = Fehler, 4 = Nicht gut, 5 = Nicht gut
default value: 0
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Betriebsstundenzähler" index=93 id=V_OperatingTime

description: Betriebsdauer in Stunden
data type: 32-bit UInteger
allowed values: 0..4294967295
access rights: ro
dynamic

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Einschaltvorgänge" index=94 id=V_StartUps

description: Anzahl der Einschaltvorgänge
data type: 32-bit UInteger
allowed values: 0..4294967295
access rights: ro
dynamic

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Maximaltemperatur" index=96 id=V_Temperature_Max

description: Maximal erreichte Betriebstemperatur in °C
data type: 16-bit Integer
allowed values: -400..1200
access rights: ro
dynamic

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Anzahl der Schaltvorgänge für SSC1.2" index=102 id=V_SSC12_SwitchCounter

description: Anzahl der Schaltvorgänge seit Gerätestart bzw. -reset für den Schaltkanal SSC1.2
data type: 32-bit UInteger
allowed values: 0..4294967295
access rights: ro
dynamic

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Status Pin 2" index=103 id=V_Pin2

description: Status Pin 2
data type: 8-bit UInteger
allowed values: 0 = Inaktiv (Gesperrt), 1 = Aktiv (Entsperrt), 2 = Open (Entsperrt)
default value: 2
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Beschreibung MDC" index=16512 id=V_SSP_MDC_Descriptor

description: Beschreibung für die Eigenschaft des Messdatenkanals (Prozessdatum MV).
data type: 88-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer Unterer Wert Zeigt den unteren Wert des Messbereichs an.
2 24 32-bit Integer Oberer Wert Zeigt den oberen Wert des Messbereichs an.
3 8 16-bit UInteger Einheit Code Zeigt den eindeutigen Code für die physikalische Einheit an.
4 0 8-bit Integer Skala Zeigt den Multiplikator für den Messwert - 10exp(Skala).

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

ErrorTypes

CodeAdditional codeNameDescription
128 (0x80)0 (0x00)Fehler in der technologiespezifischen Anwendung - keine DetailsDer Service wurde von der technologiespezifischen Anwendung verweigert. Keine weiteren Informationen zur Ursache verfügbar.
128 (0x80)17 (0x11)Index nicht vorhandenLese- oder Schreibzugriffsversuch auf einen nicht vorhandenen Index.
128 (0x80)18 (0x12)Subindex nicht vorhandenLese- oder Schreibzugriffsversuch auf einen nicht vorhandenen Subindex zu einem vorhandenen Index.
128 (0x80)32 (0x20)Service zurzeit nicht verfügbarParameter nicht erreichbar aufgrund des aktuellen Zustands der technologiespezifischen Anwendung.
128 (0x80)35 (0x23)Zugriff verweigertSchreibzugriff auf einen schreibgeschützten Parameter oder Lesezugriff auf einen nur beschreibbaren Parameter.
128 (0x80)48 (0x30)Parameterwert außerhalb des gültigen BereichsGeschriebener Parameterwert liegt außerhalb des zulässigen Wertebereichs.
128 (0x80)49 (0x31)Parameterwert oberhalb der zulässigen GrenzeGeschriebener Parameterwert überschreitet den zulässigen Wertebereich.
128 (0x80)50 (0x32)Parameterwert unterhalb der zulässigen GrenzeGeschriebener Parameterwert unterschreitet den zulässigen Wertebereich.
128 (0x80)51 (0x33)Parameterlänge überschrittenGeschriebener Parameter ist länger als erlaubt.
128 (0x80)52 (0x34)Parameterlänge unterschrittenGeschriebener Parameter ist kürzer als erlaubt.
128 (0x80)53 (0x35)Funktion nicht verfügbarGeschriebener Befehl wird von der technologiespezifischen Anwendung nicht unterstützt.
128 (0x80)54 (0x36)Funktion zurzeit nicht verfügbarGeschriebener Befehl ist im aktuellen Zustand der technologiespezifischen Anwendung nicht verfügbar.
128 (0x80)64 (0x40)Ungültiger ParametersatzGeschriebener Einzelparameterwert kollidiert mit anderen vorhandenen Parametereinstellungen.
128 (0x80)65 (0x41)Inkonsistenter ParametersatzParametersatz inkonsistent am Ende des Blockparametertransfers. Geräteplausibilitätsprüfung fehlgeschlagen.
128 (0x80)130 (0x82)Applikation nicht bereitLese- oder Schreibzugriff verweigert. Die technologiespezifische Anwendung ist zurzeit nicht erreichbar.

Events

CodeTypeNameDescription
16384 (0x4000)ErrorTemperaturfehlerÜberlast
20480 (0x5000)ErrorHardwarefehler im GerätGerät austauschen
35840 (0x8c00)ErrorFehler in der technologiespezifischen AnwendungGerät zurücksetzen
35841 (0x8c01)WarningSimulation aktivBetriebsart prüfen
36350 (0x8dfe)WarningTestevent 1Event appears by setting index 2 to value 240, Event disappears by setting index 2 to value 241
36351 (0x8dff)WarningTestevent 2Event appears by setting index 2 to value 242, Event disappears by setting index 2 to value 243

Process Data Formatting

Formatting for Process Data id=PI_ProcessDataIn
Subindex 1:
Subindex 2:
Subindex 3:
Subindex 4:

Operator Menus

Identification Menu
Identifikation
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_Lot
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag, ro
V_CP_FunctionTag, ro
V_CP_LocationTag, ro

Parameters Menu
Parameter
Sensorkanal 1
V_OperatingMode, ro
Schaltsignalkanal 1.1
V_SSC11_Param.SP1, ro
V_SSC11_Param.SP2, ro
V_SSC11_Config.Logik, ro
V_SSC11_Config.Modus, ro
V_SSC11_Config.Hyst , ro
V_SSC11_DS ms, ro
V_SSC11_DR ms, ro
Schaltsignalkanal 1.2
V_SSC12_Param.SP1, ro
V_SSC12_Param.SP2, ro
V_SSC12_Config.Logik, ro
V_SSC12_Config.Modus, ro
V_SSC12_Config.Hyst , ro
V_SSC12_DS ms, ro
V_SSC12_DR ms, ro

Diagnosis Menu
Diagnose
V_DeviceStatus
V_SSC11_SwitchCounter
V_SSC12_SwitchCounter

Maintenance Menus

Identification Menu
Identifikation
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_Lot
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag
V_SystemCommand, Button:=126
V_SystemCommand, Button:=127

Parameters Menu
Parameter
Einrichten
V_DeviceAccessLocks.Lokale Benutzerschnittstelle
V_SystemCommand, Button:=129
Description=Die Parameter der technologiespezifischen Anwendung werden auf Standardwerte gesetzt. Identifikationsparameter bleiben unverändert. Sofern in der Portkonfiguration des Masters aktiviert, wird ein Upload in den Datenspeicher des Masters ausgeführt.
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
If V_MultiIO2 = 0:
I/O
V_OutputModeinSIOMode, ro
V_MultiIO2, ro
If V_MultiIO2 = 4:
I/O
V_OutputModeinSIOMode, ro
V_MultiIO2, ro
If V_MultiIO2 = 5:
I/O
V_OutputModeinSIOMode, ro
V_MultiIO2, ro
If V_MultiIO2 = 6:
I/O
V_OutputModeinSIOMode, ro
V_MultiIO2, ro
If V_MultiIO2 = 10:
I/O
V_OutputModeinSIOMode, ro
V_MultiIO2, ro
If V_MultiIO2 = 16:
I/O
V_OutputModeinSIOMode, ro
V_MultiIO2, ro
V_Pin2
V_Pin2Polarity, ro
Sensorkanal 1
V_OperatingMode, ro
Schaltsignalkanal 1.1
V_SSC11_Param.SP1
V_SSC11_Param.SP2
V_SSC11_Config.Logik
V_SSC11_Config.Modus
V_SSC11_Config.Hyst
V_SSC11_DS ms
V_SSC11_DR ms
Schaltsignalkanal 1.2
V_SSC12_Param.SP1
V_SSC12_Param.SP2
V_SSC12_Config.Logik
V_SSC12_Config.Modus
V_SSC12_Config.Hyst
V_SSC12_DS ms
V_SSC12_DR ms

Diagnosis Menu
Diagnose
V_DeviceStatus
V_OperatingTime h
V_SSC11_SwitchCounter
V_SSC12_SwitchCounter

Commissioning Menus

Identification Menu
Identifikation
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_Lot
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag
V_SystemCommand, Button:=126
V_SystemCommand, Button:=127

Parameters Menu
Parameter
Einrichten
V_DeviceAccessLocks.Lokale Benutzerschnittstelle
V_SystemCommand, Button:=129
Description=Die Parameter der technologiespezifischen Anwendung werden auf Standardwerte gesetzt. Identifikationsparameter bleiben unverändert. Sofern in der Portkonfiguration des Masters aktiviert, wird ein Upload in den Datenspeicher des Masters ausgeführt.
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
If V_MultiIO2 = 0:
I/O
V_OutputModeinSIOMode
V_MultiIO2
If V_MultiIO2 = 4:
I/O
V_OutputModeinSIOMode
V_MultiIO2
If V_MultiIO2 = 5:
I/O
V_OutputModeinSIOMode
V_MultiIO2
If V_MultiIO2 = 6:
I/O
V_OutputModeinSIOMode
V_MultiIO2
If V_MultiIO2 = 33:
I/O
V_OutputModeinSIOMode
V_MultiIO2
If V_MultiIO2 = 34:
I/O
V_OutputModeinSIOMode
V_MultiIO2
If V_MultiIO2 = 35:
I/O
V_OutputModeinSIOMode
V_MultiIO2
If V_MultiIO2 = 10:
I/O
V_OutputModeinSIOMode
V_MultiIO2
If V_MultiIO2 = 16:
I/O
V_OutputModeinSIOMode
V_MultiIO2
V_Pin2
V_Pin2Polarity
Sensorkanal 1
V_OperatingMode
V_SystemCommand, Button:=169
Schaltsignalkanal 1.1
V_SSC11_Param.SP1
V_SSC11_Param.SP2
V_SSC11_Config.Logik
V_SSC11_Config.Modus
V_SSC11_Config.Hyst
V_SSC11_DS ms
V_SSC11_DR ms
Schaltsignalkanal 1.2
V_SSC12_Param.SP1
V_SSC12_Param.SP2
V_SSC12_Config.Logik
V_SSC12_Config.Modus
V_SSC12_Config.Hyst
V_SSC12_DS ms
V_SSC12_DR ms
Einzelwert-Teach
V_TeachSelect
V_SystemCommand, Button:=75
V_SystemCommand, Button:=77
V_TeachResult.Zustand
V_TeachQuality
Dynamic-Teach
V_TeachSelect
V_SystemCommand, Button:=71
V_SystemCommand, Button:=72
V_SystemCommand, Button:=73
V_SystemCommand, Button:=74
V_SystemCommand, Button:=79
V_TeachResult.Zustand
V_TeachQuality
Teachwerte Kanal 1.1
V_TeachValuesSSC1SP1.TP1
V_TeachValuesSSC1SP1.TP2
V_TeachValuesSSC1SP2.TP1
V_TeachValuesSSC1SP2.TP2
Teachwerte Kanal 1.2
V_TeachValuesSSC2SP1.TP1
V_TeachValuesSSC2SP1.TP2
V_TeachValuesSSC2SP2.TP1
V_TeachValuesSSC2SP2.TP2

Diagnosis Menu
Diagnose
V_DeviceStatus
Detaillierter Gerätestatus
V_DetailedDeviceStatus
Nicht rücksetzbare Diagnosedaten
V_Temperature * 0.1 °C, Dec.1
V_Temperature_Max * 0.1 °C, Dec.1
V_OperatingTime h
V_StartUps
Rücksetzbare Diagnosedaten
V_SSC11_SwitchCounter
V_SSC12_SwitchCounter
V_ProcessDataLimits.min
V_ProcessDataLimits.max
V_SystemCommand, Button:=163
Messdateninformationen
V_SSP_MDC_Descriptor

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.
Created by IODD Viewer V1.3.