Version: V1.1Release Date: 2020-10-15


LAT45
Vendor ID 545 (0x0221) Vendor Logo
Vendor Name di-soric GmbH & Co. KG
Vendor Text SOLUTIONS. CLEVER. PRACTICAL.
Vendor URL www.di-soric.com
Device ID 213 (0x0000d5)
DeviceFamily Optische Abstandssensoren
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x0001 (Device Profile: Smart Sensor), 0x8000 (Function Class: Device Identification), 0x8002 (Function Class: Process Data Variables), 0x8003 (Function Class: Device Diagnosis), 0x8004 (Function Class: Teach-In Commands)
Supported Access Locks Parameter: no, Data Storage: yes, Local Parameterization: yes, Local User Interface: no
Communication
IO-Link Revision V1.1
Compatible with V1.0
Transmission Rate38400 bit/s (COM2)
Minimum Cycle Time 5 ms
SIO Mode Supported yes
M-Sequence CapabilityPREOPERATE = TYPE_1_V with 8 octets on-request data
OPERATE = TYPE_2_V with 2 octets on-request data
ISDU supported
Device Variant LAT45-10MP3-B5
Description Optischer Abstandssensor 200...10000mm, Laser
Product ID 213004
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeNon-standard connector
Connection Symbol Connection Symbol
Connection Description M12-5
- pin 1 brown; L+; L+
- pin 2 white; Other; n.c.
- pin 3 (light) blue; L-; L-
- pin 4 black; C/Q; C/Q
- pin 5 grey (slate); Other; In

ProcessData id=V_PdT

ProcessDataIn "Prozessdaten Eingang" id=V_PdInT

bit length: 64
data type: 64-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 48 16-bit Integer -32760 = Außerhalb Bereich (-), 32760 = Außerhalb Bereich (+), 32764 = Keine Messdaten, 200..9999 Entfernung Aktuelle Entfernung des Objekts
2 16 16-bit Integer -32760 = Außerhalb Bereich (-), 32760 = Außerhalb Bereich (+), 32764 = Keine Messdaten, 1..100 Reflektivität Reflektivität des Messobjekts
3 0 Boolean false = Inaktiv, true = Aktiv Schaltzustand (SSC2, Q2) Status depends on Q1
Octet 0
bit offset 63 62 61 60 59 58 57 56
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 55 54 53 52 51 50 49 48
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 47 46 45 44 43 42 41 40
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 3
bit offset 39 38 37 36 35 34 33 32
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 4
bit offset 31 30 29 28 27 26 25 24
subindex 2
element bit 15 14 13 12 11 10 9 8
Octet 5
bit offset 23 22 21 20 19 18 17 16
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 6
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 7
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 3

Standard Variable "Direkte Parameter 1" index=0 id=V_DirectParameters_1

data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserviert
2 112 8-bit UInteger ro Master Zykluszeit
3 104 8-bit UInteger ro Minimale Zykluszeit
4 96 8-bit UInteger ro Telegramm-Fähigkeit
5 88 8-bit UInteger 17 ro IO-Link Versions-ID
6 80 8-bit UInteger ro Prozessdatenlänge Eingang
7 72 8-bit UInteger ro Prozessdatenlänge Ausgang
8 64 8-bit UInteger ro Hersteller-ID 1
9 56 8-bit UInteger ro Hersteller-ID 2
10 48 8-bit UInteger ro Geräte-ID 1
11 40 8-bit UInteger ro Geräte-ID 2
12 32 8-bit UInteger ro Geräte-ID 3
13 24 8-bit UInteger ro Reserviert
14 16 8-bit UInteger ro Reserviert
15 8 8-bit UInteger ro Reserviert
16 0 8-bit UInteger 67 = Teach SP TP1, 68 = Teach SP TP2, 75 = Teach ohne Objekt, 130 = Auslieferungszustand wiederherstellen, 164 = Messung stoppen, 165 = Messung starten, 240 = IO-Link 1.1 system test command 240, Event 8DFE appears, 241 = IO-Link 1.1 system test command 241, Event 8DFE disappears, 242 = IO-Link 1.1 system test command 242, Event 8DFF appears, 243 = IO-Link 1.1 system test command 243, Event 8DFF disappears wo X Standardkommando

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Direkte Parameter 2" index=1 id=V_DirectParameters_2

data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger Gerätespezifischer Parameter 1
2 112 8-bit UInteger Gerätespezifischer Parameter 2
3 104 8-bit UInteger Gerätespezifischer Parameter 3
4 96 8-bit UInteger Gerätespezifischer Parameter 4
5 88 8-bit UInteger Gerätespezifischer Parameter 5
6 80 8-bit UInteger Gerätespezifischer Parameter 6
7 72 8-bit UInteger Gerätespezifischer Parameter 7
8 64 8-bit UInteger Gerätespezifischer Parameter 8
9 56 8-bit UInteger Gerätespezifischer Parameter 9
10 48 8-bit UInteger Gerätespezifischer Parameter 10
11 40 8-bit UInteger Gerätespezifischer Parameter 11
12 32 8-bit UInteger Gerätespezifischer Parameter 12
13 24 8-bit UInteger Gerätespezifischer Parameter 13
14 16 8-bit UInteger Gerätespezifischer Parameter 14
15 8 8-bit UInteger Gerätespezifischer Parameter 15
16 0 8-bit UInteger Gerätespezifischer Parameter 16

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Standardkommando" index=2 id=V_SystemCommand

data type: 8-bit UInteger
allowed values: 67 = Teach SP TP1, 68 = Teach SP TP2, 75 = Teach ohne Objekt, 130 = Auslieferungszustand wiederherstellen, 164 = Messung stoppen, 165 = Messung starten, 240 = IO-Link 1.1 system test command 240, Event 8DFE appears, 241 = IO-Link 1.1 system test command 241, Event 8DFE disappears, 242 = IO-Link 1.1 system test command 242, Event 8DFF appears, 243 = IO-Link 1.1 system test command 243, Event 8DFF disappears
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Gerätezugriffssperren" index=12 id=V_DeviceAccessLocks

data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean Parameter (Schreib-)Zugriffssperre
2 1 Boolean false Datenspeicherungssperre
3 2 Boolean false Lokale Parameterisierungssperre
4 3 Boolean Lokale Benutzerinterface-Sperre
Octet 0
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4 3 2 1

Standard Variable "Herstellername" index=16 id=V_VendorName

data type: 26-octet String UTF-8
default value: "di-soric GmbH & Co. KG"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144

octet 8 9 10 11 12 13 14 15
bit offset 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80

octet 16 17 18 19 20 21 22 23
bit offset 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16

octet 24 25  
bit offset 15 - 8 7 - 0  

Standard Variable "Herstellertext" index=17 id=V_VendorText

data type: 29-octet String UTF-8
default value: "SOLUTIONS. CLEVER. PRACTICAL."
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168

octet 8 9 10 11 12 13 14 15
bit offset 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104

octet 16 17 18 19 20 21 22 23
bit offset 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40

octet 24 25 26 27 28  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Produktname" index=18 id=V_ProductName

data type: 14-octet String UTF-8
default value: "LAT45-10MP3-B5"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48

octet 8 9 10 11 12 13  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Produkt-ID" index=19 id=V_ProductID

data type: 14-octet String UTF-8
default value: "LAT45-10MP3-B5"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48

octet 8 9 10 11 12 13  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Produkttext" index=20 id=V_ProductText

data type: 23-octet String UTF-8
default value: "Optical distance sensor"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120

octet 8 9 10 11 12 13 14 15
bit offset 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56

octet 16 17 18 19 20 21 22  
bit offset 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Seriennummer" index=21 id=V_SerialNumber

data type: 12-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32

octet 8 9 10 11  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Hardwareversion" index=22 id=V_HardwareRevision

data type: 8-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmwareversion" index=23 id=V_FirmwareRevision

data type: 8-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Anwendungsspezifische Markierung" index=24 id=V_ApplicationSpecificTag

data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Gerätestatus" index=36 id=V_DeviceStatus

data type: 8-bit UInteger
allowed values: 0 = Gerät ist OK, 1 = Wartung erforderlich, 2 = Außerhalb der Spezifikation, 3 = Funktionsprüfung, 4 = Fehler, 5..255 = Reserviert
default value: 0
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Ausführlicher Gerätestatus" index=37 id=V_DetailedDeviceStatus

data type: Array[8] of 3-octet OctetString (subindex access not supported)
default value: 0x00,0x00,0x00
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 1 1 1 2 2 2 3 3

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 3 4 4 4 5 5 5 6

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 6 6 7 7 7 8 8 8

Standard Variable "Prozessdaten Eingang" index=40 id=V_ProcessDataInput

data type: see ProcessDataIn!
access rights: ro
dynamic

Variable "Teach-in Auswahl" index=58 id=V_TI-Select

description: Adressierung eines bestimmten SSC auf welchen teach-in Kommandos angewendet werden sollen
data type: 8-bit UInteger
allowed values: 1 = Switch state (SSC1, Q1)
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Teach Status" index=59 id=V_TI-Result

description: Teach result
data type: 8-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 5 Boolean false = Nok, true = Ok 0 Flag SP1 TP2 Feedback for SP1, teach point 2
2 4 Boolean false = Nok, true = Ok 0 Flag SP1 TP1 Feedback for SP1, teach point 1
3 0 4-bit UInteger 0 = Nicht aktiv, 1 = Schaltpunkt 1 gesetzt, 4 = Warten auf Kommando, 5 = Aktiv, 7 = Fehler 0 Teach Status Zustand Teach-In
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / 1 2 3
element bit         3 2 1 0

Variable "Betriebsstundenzähler" index=93 id=V_Operating_Hours

description: Einschaltdauer
data type: 32-bit Integer
allowed values: 0..2147483647
default value: 0
access rights: ro
dynamic

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Einschaltvorgänge" index=94 id=V_Number_Of_Powercycles

description: Einschaltvorgänge
data type: 32-bit Integer
allowed values: 0..2147483647
default value: 0
access rights: ro
dynamic

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Einschaltverzögerung Schaltausgang" index=370 id=V_SSC1_dS

description: Einschaltverzögerung Schaltausgang
data type: 16-bit UInteger
allowed values: 0..5000
default value: 0
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Ausschaltverzögerung Schaltausgang" index=371 id=V_SSC1_dr

description: Ausschaltverzögerung Schaltausgang
data type: 16-bit UInteger
allowed values: 0..5000
default value: 0
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Fehlerunterdrückungszeit Ausgänge" index=530 id=V_dFo

description: Verzögerungszeit der Ausgänge im Fehlerfall
data type: 16-bit UInteger
allowed values: 0..5000
default value: 0
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Key-lock" index=550 id=V_Loc

description: Key-lock verriegelt die Sensorbedienung zum Schutz vor ungewollter Verstellung. Key-lock kann am Gerät zurückgesetzt werden
data type: 8-bit UInteger
allowed values: 0 = Aktiviert, 1 = Deaktiviert
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Funktion Ausgang (Pin 4)" index=580 id=V_ou1

description: Ausgangkonfiguration Out 1
data type: 8-bit UInteger
allowed values: 3 = Schaltpunkt Modus, NO, 4 = Schaltpunkt Modus, NC, 16 = Deaktiviert
default value: 3
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Schaltpunkt SSC1" index=583 id=V_SP1

description: Schaltpunkt 1
data type: 16-bit Integer
allowed values: 200..9999
default value: 9999
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Aktualisierungsrate Anzeige" index=800 id=V_diS-U

description: Aktualisierungsrate der Anzeige am Gerät
data type: 8-bit UInteger
allowed values: 0 = schnell, 1 = mittel, 2 = langsam
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Drehung" index=801 id=V_diS-R

description: Aktuelle Drehung der Anzeige am Gerät im Uhrzeigersinn
data type: 8-bit UInteger
allowed values: 0 = 0 °, 2 = 180 °
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Display" index=802 id=V_diS-B

description: Aktueller Status der Anzeige am Gerät
data type: 8-bit UInteger
allowed values: 0 = Deaktiviert, 1 = Aktiviert
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Transmitter configuration" index=2000 id=V_Transmitter_Configuration

description: Konfiguration Sendelicht
data type: 8-bit UInteger
allowed values: 0 = Deaktiviert, 1 = Aktiviert, 2 = Ausschalten mit externem Signal (Pin 5) aktiv, 3 = Einschalten mit externem Signal (Pin 5) aktiv
default value: 2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Reproduzierbarkeit" index=2008 id=V_Repr_ro

description: Bei unveränderter Situation bleibt der Messwert (PDV oder Analogausgang) mit hoher Wahrscheinlichkeit innerhalb dieser Schwankungsbreite.
data type: 16-bit UInteger
allowed values: 0..9999
access rights: ro

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

ErrorTypes

CodeAdditional codeNameDescription
128 (0x80)0 (0x00)Anwendungsfehler im Gerät - keine DetailsZugriff wurde vom Gerät verweigert. Es steht keine Detailinformation zur Verfügung
128 (0x80)17 (0x11)Index nicht vorhandenZugriff auf einen nicht existierenden Index
128 (0x80)18 (0x12)Subindex nicht vorhandenZugriff auf einen nicht existierenden Subindex
128 (0x80)32 (0x20)Service zur Zeit nicht verfügbarAuf den Parameter kann gerade nicht zugegriffen werden. Das Gerät erlaubt dies im aktuellen Zustand nicht
128 (0x80)33 (0x21)Service zur Zeit nicht verfügbar - lokaler BetriebsmodusAuf den Parameter kann gerade nicht zugegriffen werden, da sich das Gerät zur Zeit in einem lokalen Betriebsmodus befindet
128 (0x80)34 (0x22)Service zur Zeit nicht verfügbar - Geräte BetriebsmodusAuf den Parameter kann gerade nicht zugegriffen werden, da sich das Gerät zur Zeit in einem Remote Betriebsmodus befindet
128 (0x80)35 (0x23)Zugriff verweigertSchreibzugriff auf einen schreibgeschützten Parameter
128 (0x80)48 (0x30)Parameterwert außerhalb des gültigen BereichsGeschriebener Parameterwert liegt außerhalb des zulässigen Wertebereichs
128 (0x80)51 (0x33)Parameterlänge zu großGeschriebene Parameterlänge ist größer als erlaubt
128 (0x80)52 (0x34)Parameterlänge zu kleinGeschriebene Parameterlänge ist kleiner als erlaubt
128 (0x80)53 (0x35)Funktion nicht verfügbarGeschriebenes Kommando wird vom Gerät nicht unterstützt
128 (0x80)54 (0x36)Funktion zur Zeit nicht verfügbarGeschriebenes Kommando wird vom Gerät im aktuellen Zustand nicht unterstützt
128 (0x80)64 (0x40)Ungültiger ParametersatzGeschriebener Einzelparameterwert kollidiert mit den anderen Parametereinstellungen
128 (0x80)65 (0x41)Inkonsistenter ParametersatzAm Ende des Blockparametertransfers wurden Inkonsistenzen erkannt. Der Geräteplausibilitätscheck schlug fehl
128 (0x80)130 (0x82)Applikation nicht bereitZugriff wurde verweigert, da das Gerät zur Zeit nicht bereit ist

Events

CodeTypeNameDescription
16912 (0x4210)WarningZulässige Gerätetemperatur überschrittenLokalisieren Sie die Wärmequelle
16928 (0x4220)WarningZulässige Gerätetemperatur unterschrittenIsolieren Sie das Gerät
36004 (0x8ca4)WarningPlausibilitätsfehler in der MessungÜberprüfen Sie Ihre Applikation
36016 (0x8cb0)WarningNEAR - Objekt zu nah am SensorDas Gerät kann noch messen - jedoch außerhalb der Datenblatt-Spezifikation
36017 (0x8cb1)WarningFAR - Objekt zu fern vom SensorDas Gerät kann noch messen - jedoch außerhalb der Datenblatt-Spezifikation
36056 (0x8cd8)WarningZu viel LichtÜberprüfen Sie Ihre Applikation
36057 (0x8cd9)WarningZu wenig LichtÜberprüfen Sie Ihre Applikation
36350 (0x8dfe)WarningTest Event 1Event appears by setting index 2 to value 240, Event disappears by setting index 2 to value 241
36351 (0x8dff)WarningTest Event 2Event appears by setting index 2 to value 242, Event disappears by setting index 2 to value 243

Process Data Formatting

Formatting for Process Data id=V_PdInT
Subindex 1: mm
Subindex 2: %
Subindex 3:
Subindex 4:

Observer Menus

Identification Menu
V_VendorName
V_ProductName
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag, ro

Parameter Menu
Ausgangskonfiguration
V_ou1, ro
If V_ou1 = 3:
Schaltausgang (Pin 4)
V_SP1 * 1 + 0 mm, ro Dec.0
If V_ou1 = 4:
Schaltausgang (Pin 4)
V_SP1 * 1 + 0 mm, ro Dec.0

Observation Menu
Prozessdaten Eingang
V_ProcessDataInput.1 * 1 + 0 mm, Dec.0
V_ProcessDataInput.2 * 1 + 0 %, Dec.0
V_ProcessDataInput.3

Diagnosis Menu
Diagnose
V_DeviceStatus

Maintenance Menus

Identification Menu
V_VendorName
V_ProductName
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag, ro

Parameter Menu
Ausgangskonfiguration
V_ou1, ro
If V_ou1 = 3:
Schaltausgang (Pin 4)
V_SP1 * 1 + 0 mm, Dec.0
If V_ou1 = 4:
Schaltausgang (Pin 4)
V_SP1 * 1 + 0 mm, Dec.0

Observation Menu
Prozessdaten Eingang
V_ProcessDataInput.1 * 1 + 0 mm, Dec.0
V_ProcessDataInput.2 * 1 + 0 %, Dec.0
V_ProcessDataInput.3

Diagnosis Menu
Diagnose
V_DeviceStatus
V_Number_Of_Powercycles * 1 + 0, Dec.0

Specialist Menus

Identification Menu
V_VendorName
V_ProductName
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag

Parameter Menu
Setup
V_DeviceAccessLocks.Datenspeicherungssperre
V_DeviceAccessLocks.Lokale Parameterisierungssperre
V_SystemCommand, Button:=130
Ausgangskonfiguration
V_ou1
If V_ou1 = 3:
Schaltausgang (Pin 4)
V_SP1 * 1 + 0 mm, Dec.0
V_SSC1_dS * 0.001 + 0 s, Dec.3
V_SSC1_dr * 0.001 + 0 s, Dec.3
If V_ou1 = 4:
Schaltausgang (Pin 4)
V_SP1 * 1 + 0 mm, Dec.0
V_SSC1_dS * 0.001 + 0 s, Dec.3
V_SSC1_dr * 0.001 + 0 s, Dec.3
Display und Tastatur Einstellungen
V_diS-U
V_diS-R
V_diS-B
V_Loc
Zusätzliche Funktionen
V_dFo * 0.001 + 0 s, Dec.3
V_SystemCommand, Button:=164
V_SystemCommand, Button:=165
V_Transmitter_Configuration
If V_ou1 = 3:
Teach SSC
V_TI-Select
V_TI-Result.Teach Status
V_SystemCommand, Button:=67
V_SystemCommand, Button:=68
V_SystemCommand, Button:=75
If V_ou1 = 4:
Teach SSC
V_TI-Select
V_TI-Result.Teach Status
V_SystemCommand, Button:=67
V_SystemCommand, Button:=68
V_SystemCommand, Button:=75

Observation Menu
Prozessdaten Eingang
V_ProcessDataInput.1 * 1 + 0 mm, Dec.0
V_ProcessDataInput.2 * 1 + 0 %, Dec.0
V_ProcessDataInput.3

Diagnosis Menu
Diagnose
V_DeviceStatus
V_Repr_ro * 1 + 0 mm, Dec.0
V_Operating_Hours * 1 + 0 h, Dec.0
V_Number_Of_Powercycles * 1 + 0, Dec.0

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.
Created by IODD Viewer V1.1.